APPENDIXB. ALARM LIST
B–63325EN/03
466
Number ContentsMessage
SR0965 DIRECTORY FULL (MEMORY CARD) The file could not be generated in the root directory for the memory card.
SR0966 FILE NOT FOUND (MEMORY CARD) The specified file could not be found on the memory card.
SR0967 FILE PROTECTED (MEMORY CARD) The memory card is write–protected.
SR0968 ILLEGAL FILE NAME (MEMORY CARD) Illegal memory card file name
SR0969 ILLEGAL FORMAT (MEMORY CARD) Illegal memory card format
SR0970 ILLEGAL CARD (MEMORY CARD) This memory card cannot be handled.
SR0971 ERASE ERROR (MEMORY CARD) An error occurred during memory card erase.
SR0972 BATTERY LOW (MEMORY CARD) The memory card battery is low.
SR0973 FILE ALREADY EXIST A file having the same name already exists on the memory card.
SR1030 NOT READY (DATA SERVER) The board is not ready in the Ethernet/data server board function.
SR1031 BUSY (DATA SERVER) The board is busy in the Ethernet/data server board function.
SR1032 BOARD ERROR (DATA SERVER) An error was returned from the board in the Ethernet/data server board
function.
SR1033 TIME OVER (DATA SERVER) The CNC registered a time–out in the Ethernet/data server board
function.
SR1034 CNC ERROR (DATA SERVER) An internal CNC error occurred by the Ethernet/data server board
function.
SR1035 SEQUENCE ERROR (DATA SERVER) A contradiction occurred in the CNC by the Ethernet/data server board
function.
SR1036 MODE ERROR (DATA SERVER) The mode could not be changed in the Ethernet/data server board
function.
SR1037 DOUBLE OPEN (DATA SERVER) An attempt was made to open the file twice in the Ethernet/data server
board function.
SR1040 Device open error (Remote DGN.) An error occurred in an attempt to open an I/O device for remote
diagnosis.
SR1041 Illegal command (Remote DGN.) An invalid command was specified for an I/O device for remote
diagnosis.
SR1042 Data input error (Remote DGN.) An error occurred during data input to an I/O device for remote
diagnosis.
SR1043 Data output error (Remote DGN.) An error occurred during data output from an I/O device for remote
diagnosis.
SR1050 #200–#999ILLEGAL INPUT (UNMATCHED
P–CODE MACRO COMMON)
The settings of parameters MV0 through MVA (bit 0 of No. 8503 through
bit 3 of No. 8504) do not match the common variable data to be entered.
SR1051 #200–#499ILLEGAL P–CODE MACRO
COMMON INPUT (NO OPTION)
An attempt was made to enter a custom macro common variable that is
not used with the system.
SR1052 #500–#549P–CODE MACRO COMMON
SELECT (CANNOT USE SETVN)
Variable names cannot be entered.
SETVN cannot be specified for P–code macro common variables #500
through #549.
SR1053 THE NUMBER OF #30000 IS UNMATCH An attempt was made to enter a P–code–dedicated variable that is not
used with the system.
SR1054 THE NUMBER OF #40000 IS UNMATCH An attempt was made to enter an extended P–code–dedicated variable
that is not used with the system.