FANUC LTD
ED
FANUC Series 16i-MA
SYNCHRONOUS CONTROL BETWEEN 2 PATH
01
TAKEUCHI
TAKEUCHI
3. Parameters
#7 #6 #5 #4 #3 #2 #1 #0
8160
NRS NCS
Data format : Bit type
NCS When the axis of synchronous control becomes overtravel alarm,
0:Synchronous control are released.
1:Synchronous control are not released.
(note) When the axis which execute synchronous control
becomes overtravel alarm, the system becomes by setting
this parameter as follows.
NCS:0
The P/S225 alarm might be generated with overtravel alarm. In
this case, please put into the state of the emergency stop once and
release the alarm.
NCS:1
The system is decelerated and stopped delaying 8msec than usual
overtravel alarm.
NRS
0 : Synchronous control are released by the reset.
1 : Synchronous control are not released by the reset.
8180 Synchronous master axis of each axis
Data format : Byte axis type
Data range : 1, 2, 3,...., Number of controlled axis
The axis index of the master axis which synchronizes of each axis is set. The
axis which 0 is set, does not become slave axis which moves synchronizing with
other axes.
The same number can be set in two parameters or more and it make it to a master
one axis and an axis two or more slave.
The axis index of the corresponding synchronous master axis set in the parameter
of the synchronous slave axis.
Setting value 1,2,3,...,8