APPENDIX
B–63665EN/01
A. ALARM LIST
359
Number ContentsMessage
5057 M–NET BOARD SYSTEM DOWN Transmit time–out error (parameter No. 177)
ROM parity error
CPU interruption detection of not listed above
5059 RADIUS VALUE OUTSIDE ALLOW-
ABLE RANGE
When the center of the arc was specified by I, J, and K for circular
interpolation, the length of the radius value exceeded nine digits.
5063 IS NOT PRESET AFTER REF. This message is output when the position counter has not been
preset before the start of plate thickness measurement. This alarm is
issued in one of the cases below.
1) When an attempt was made to perform measurement before a refer-
ence position had been established.
2) When, after manual reference position return, an attempt was made
to start measurement without first setting the position counter.
5064 DIFFERRENT AXIS UNIT
(IS–B, IS–C)
Circular interpolation was specified for a plane formed by axes using
different increment systems.
5065 DIFFERRENT AXIS UNIT
(PMC AXIS)
In PMC–based axis control, axes using different increment systems
are specified for the same DI/DO group. Modify parameter No. 8010.
5068 G31 P90 FORMAT ERROR No axis is specified for movement.
Two or more axes were specified for movement.
5073 NO DECIMAL POINT A decimal point is not specified for a command for which a decimal
point must be specified.
5074 ADDRESS DUPLICATION ERROR The same address appears more than once in a block. Alternatively,
a block contains two or more G codes belonging to the same group.
5082 DATA SERVER ERROR Details are displayed on the data server message screen.
5110 IMPROPER G–CODE
(G05.1 G1 MODE)
An illegal G code was specified in AI contour control mode.
5111 IMPROPER MODAL G–CODE
(G05.1 G1)
An illegal G code is left modal when AI contour control mode was speci-
fied.
5112 G08 CAN NOT BE COMMANDED
(G05.1 G1)
Look–ahead control (G08) was specified in AI contour control mode.
5113 CAN NOT ERROR IN MDI MODE
(G05.1)
AI contour control (G05.1) was specified in MDI mode.
5114 NOT STOP POSITION
(G05.1 Q1)
At the time of restart after manual intervention, the coordinates at which
the manual intervention occurred have not been restored.
5134 FSSB : OPEN READY TIME OUT Initialization did not place FSSB in the open ready state.
5135 FSSB : ERROR MODE FSSB has entered error mode.
5136 FSSB : NUMBER OF AMPS IS
SMALL
In comparison with the number of controlled axes, the number of amplifi-
ers recognized by FSSB is not enough.
5137 FSSB : CONFIGURATION ERROR FSSB detected a configuration error.
5138 FSSB : AXIS SETTING NOT COM-
PLETE
In automatic setting mode, axis setting has not been made yet.
Perform axis setting on the FSSB setting screen.
5139 FSSB : ERROR Servo initialization did not terminate normally.
The optical cable may be defective, or there may be an error in connec-
tion to the amplifier or another module.
Check the optical cable and the connection status.
5156 ILLEGAL AXIS OPERATION
(AICC)
In AICC mode, the controlled axis selection signal (PMC axis control)
changes.
In AICC mode, the simple synchronous axis selection signal changes.
(AICC: AI contour control)
5157 PARAMETER ZERO (AICC) Zero is set in the parameter for the maximum cutting feedrate (parame-
ter No. 1422 or 1432).
Zero is set in the parameter for the acceleration/deceleration before in-
terpolation (parameter No. 1770 or 1771).
Set the parameter correctly.
(AICC: AI contour control)