B-70315EN/02 APPENDIX E.PARAMETER LIST
- 333 -
15328 Pulse duty cycle command for aging
[Data type] Word
[Unit of data] %
[Valid data range] 0 to 100
15329 Power command time for aging
[Data type] Word
[Unit of data] sec
[Valid data range] 0 to 32767
15330 Gas pressure setting (50 Hz) for aging
[Data type] Word
[Unit of data] (1=13Pa)
[Valid data range] 0 to 32767
15331 Gas pressure setting (60 Hz) for aging
[Data type] Word
[Unit of data] (1=13Pa)
[Valid data range] 0 to 32767
15332 Oscillation frequency command value for power compensation
[Data type] Word
[Unit of data] Hz
[Valid data range] 5 to 2000
15333 Pulse duty cycle command during power compensation
[Data type] Word
[Unit of data] %
[Valid data range] 0 to 100
15334 Number of aging operations
[Data type] Word
[Unit of data]
[Valid data range] 0 to 32767 (Automatically set by the CNC)
15335 Time data 1 when the HV is turned off after LSTR
[Data type] 2-word
[Unit of data] Year
[Valid data range] 0 to 99999999 (Automatically set by the CNC)