B-65282EN/05 9.CONNECTION
- 177 -
See Subsection 9.4 for detailed explanations about the specification of
the D-5000.
NOTE
Tyco Electronics AMP D-5000 series
Select a contact size according to the cross-section
area of the cable.
(3) For PSM-HV
Circuit
breaker 1
Magnetic
contactor
AC
reactor
(L1)
(L2)
(L3)
TB2
PSM-HV
R
S
T
Main power
supply
400VAC
to
480VAC
50/60Hz
L1
L2
L3
G
Table.9.3.1.1(b) Cable K1 Specifications
Applicable cable
Model
Heavy-duty
power cable
(Note 1)
Heat-resistant cable
(Note 2)
Terminal
screw
Tightening
torque
PSM-11HVi
5.5 mm
2
or more 5.5mm
2
or more
PSM-18HVi
-8mm
2
or more
M4 1.1 to 1.5Nm
PSM-30HVi
- 14mm
2
or more
PSM-45HVi
- 22mm
2
or more
M6 3.5 to 4.5Nm
PSM-75HVi
-
R,S,T: 38mm
2
or more
G: 22mm
2
or more
M10
M6
R,S,T: 80mm
2
or more M10
PSM-100HVi
-
G: 40mm
2
or more M6
NOTE
1 Four-conductor polyvinyl heavy-duty power cable
(JIS C3312) (VCT : heat-resistant 60°C)
2 Fire-retardant polyflex wire (heat-resistant 105°C) or
equivalent to LMFC manufactured by The Furukawa
Electric Co., Ltd.
3 The cross-section area of each cable is determined
under the following conditions:
(1) At PSM rated output
(2) Environment temperature of cable : 30°C
(3) Number of harnesses
3 (No current flows through the ground wire
during normal operation.)
Select a required cable cross-section area
according to the user environment and conditions.