4.HOW TO SELECT THE MODULE B-65282EN/05
- 74 -
4.2 HOW TO SELECT THE SPINDLE AMPLIFIER MODULE
(SPM)
First, select a spindle motor, based on the machine specification.
Then, select an appropriate spindle amplifier module for the selected
spindle motor.
Spindle amplifier modules and standard motors that can be used
together are shown below. When using a built-in motor or a motor
with special specifications, refer to relevant specifications, and select
a spindle amplifier module accordingly.
Table 4.2(a) Specification
No Ordering number Input voltage Remarks
1 A06B-6111-Hxxx#H550 200V TYPE A
2 A06B-6112-Hxxx#H550 200V TYPE B
3 A06B-6116-Hxxx#H560 200V
4 A06B-6121-Hxxx#H550 400V TYPE A
5 A06B-6122-Hxxx#H550 400V TYPE B
Table 4.2(b) Specification
200-V input series 400-V input series
Spindle amplifier for α
αα
αCi
(200-V input)
SPM-2.2i SPM-5.5HVi SPMC-2.2i
SPM-5.5i SPM-11HVi SPMC-5.5i
SPM-11i SPM-15HVi SPMC-11i
SPM-15i SPM-30HVi SPMC-15i
SPM-22i SPM-45HVi SPMC-22i
SPM-26i SPM-75HVi
SPM-30i SPM-100HVi
SPM-45i
SPM-55i