
13. FUNCTIONS TO SIMPLIFY
PROGRAMMING
B–64112EN/01
NC FUNCTION
118
D Even if the feedrate override select signal is enabled, setting the
override cancel signal to 1 causes 100% override to be applied to a
cut–in operation. If pull–out override is enabled, it is applied to the
pull–out operation.
The following table lists rigid tapping versus override value
correspondence.
Rigid tapping versus feedrate override value correspondence
Cut–in
operation
Pull–out
operation
Feedrate override = Disabled
Pull–out override = Disabled
100% 100%
Feedrate override = Disabled
Pull–out override = Enabled
100% Pull–out
override (*)
= Enabled
Pull–out override
Override
cancel signal
<G006#4>=0
Feedrate
override signal
value
Feedrate
override signal
value
Override
cancel signal
<G006#4>=1
100% 100%
= Enabled
Pull–out override
Override
cancel signal
<G006#4>=0
Feedrate
override signal
value
Feedrate
override signal
value
Override
cancel signal
<G006#4>=1
100% Pull–out
override (*)
* The pull–out override can be any of the following:
<1> Parameter–set pull–out override
<2> Program–specified pull–out override
<3> Rigid tapping return–based pull–out override