B–64112EN/01
26. DISPLAYING AND SETTING DATA
NC FUNCTION
249
On the servo setting screen, parameters required for standard initialization
of the servo motor are listed. The parameters can also be set.
SERVO SETTING O0000 N00000
X AXIS Y AXIS
INITIAL SET BIT 00000011 00000001
MOTOR ID NO. 12 12
AMR 00011111 00011111
CMR 2 2
FEEDGEAR N 3 3
(N/M) M 10 10
DIRECTION SET 111 111
VEROCITY PULSE NO. 8000 8000
POSITION PULSE NO. 8000 8000
REF COUNTER 8000 8000
MDI **** *** *** *** 09:36:48
[ SV.SET ][ SV.TUN ][ ][ ][ (OPRT) ]
On the servo adjustment screen, parameters required for basic adjustment
of the servo motor and statuses being monitored are listed for each axis.
SERVO SETTING O1000 N00000
X AXIS
(PARAMETR) (MONITOR)
FUNC.BIT 00110100 ALARM 1 00110100
LOOP GAIN 3000 ALRAM 2 00110100
TUNING ST. 1 ALARM 3 00000000
SET PERIOD 50 ALARM 4 00000000
INT.GAIN 251 LOOP GAIN 3000
PROP.GAIN –2460 POS ERROR 100
FILTER 2450 CURRENT % 50
>_
MEM STAT MTN *** *** 09:36:48
[ SV.SET ][ SV.TUN ][ ][ ][ (OPRT) ]
26.9
SCREENS FOR
SERVO DATA AND
SPINDLE DATA
26.9.1
Servo Setting Screen
26.9.2
Servo Adjustment
Screen