B–64112EN/01
6. REFERENCE POSITION
NC FUNCTION
65
The linear scale with absolute addressing reference marks has reference
marks (one–rotation signals) at intervals that change at a constant rate.
By determining the reference mark interval, the corresponding absolute
position can be deduced. The CNC makes a small movement along an
axis to measure the one–rotation signal interval, then calculates the
absolute position. The reference position can be established without
performing positioning to the reference position.
Reference
mark 1
Reference
mark 2
Reference
mark 1
Reference
mark 2
Reference
mark 1
10.02
10.04
20.02
20.00
20.00
10.06
Fig. 6.8 Sample linear scale with absolute addressing reference marks
The linear scale expansion function with absolute addressing reference
marks which is an optional function measures the reference mark interval
automatically to establish a reference position when a G00 command or
a jog–feed movement is specified.
6.8
LINEAR SCALE WITH
ABSOLUTE
ADDRESSING
REFERENCE MARKS
6.9
LINEAR SCALE
EXPANSION
FUNCTION WITH
ABSOLUTE
ADDRESSING