B–63833EN/03
7. SERVO INTERFACE
93
The interface unit can feed 0.35 A (5 V) to each separate detector.
Item Specification
Power supply capacity Voltage 24 VDC ±10%
Current 0.9 A (basic unit only)
1.5 A (basic unit + expansion unit)
Ordering information A02B–0236–C205 (basic)
Method of installation An interface unit can be installed by using
screws or a DIN rail.
Power to the separate detector interface unit should be supplied from an
external 24 V DC power supply.
CP11A
+24V (1)
0V (2)
0V
1
3
+24V
2
Separate detector interface unit
External power supply
24 V DC regulated
power supply
24 V DC "10%
Cable
CP11A
AMP JAPAN
1–178288–3 (Housing)
1–175218–5 (Contact)
External power
supply
Select a connector that
matches the pin layout
of the external power
supply.
Recommended cable specification: A02B–0124–K830 (5 m)
(The external power supply end of the cable is provided with M3 crimp
terminals.)
The 24 V DC input to CP11A can be output at CP11B for use in branching.
The connection of CP11B is identical to that of CP11A. In this case, the
power supplied to CP11A should be equal to the sum of the rating of the
separate detector interface unit and that of the units after CP11B.
7.1.4
Separate Detector
Interface Unit
Specification
7.1.5
Connection of Power
Supply