PMC Program Conversion Tool
Operator’s Manual
001 04.08.09 M.Ichijo New A-79700E
EDIT
DATE
DESIG.
DESCRIPTION
28/97
TITLE
DRAW.NO.
SHEET
CUST.
TITLE
5.1 ADDRESS / SYMBOL / COMMENT
Correspondence of references
PMC-SB7 and PMC-SD7 have the same mapping and classifications of
reference addresses. Following table describes the correspondence of
these PMCs. Please note that there are some references that cannot be
used on PMC-SD7 even if they can be used on PMC-SB7.
Remarks PMC-SB7 references PMC-SD7 references Remarks
Input from I/O Link 1st channel
Input from I/O Link 2nd channel
Input from built-in I/O
X0.0 - X127.7
X200.0 - X327.7
X1000.0 - X1127.7
%I1- %I1024
%I10001 - %I11024
%I80001 - %I81024
Output to I/O Link 1st channel
Output to I/O Link 2nd channel
Output to built-in I/O
Y0.0 - Y127.7
Y200.0 - Y327.7
Y1000.0 - Y1127.7
%Q1- %Q1024
%Q10001 - %Q11024
%Q80001 - %Q81024
Input from CNC F0.0 - F767.7
F1000.0 - F1767.7
F2000.0 - F2767.7
F3000.0 - F3767.7
%IF1- %IF6144
%IF10001 - %IF16144
%IF20001 - %IF26144
%IF30001 - %IF36144
Output to CNC G0.0 - G767.7
G1000.0 - G1767.7
G2000.0 - G2767.7
G3000.0 - G3767.7
%QG1- %QG6144
%QG10001 - %QG16144
%QG20001 - %QG26144
%QG30001 - %QG36144
Internal relay R0.0 - R7999.7 %M1- %M64000
E0.0 - E7999.7 %ME1- %ME64000
Message display request A0.0 - A249.7 %MA1- %MA2000
Counter address C0.0 – C399.7 Not exists
Internal relay K0.0 - K99.7 %MK1- %MK800
Timer address T0.0-T499.7 Not exists
Data Register D0.0 - D9999.7 %R1- %R5000 Attribute is different
%R can not be accessed by
bit width.
Label address L1-L9999 Not exists
Sub program address P1-P2000 Not exists
System area R9000.0 - R9007.7 Not exists
R9016.0 - R9499.7 %S1- %S3872
R9008.0 - R9015.7 %ST1- %ST64
A9000.0 - A9249.7 %SA1- %SA2000
K900.0 - K919.7 %SK1- %SK160