PMC Program Conversion Tool
Operator’s Manual
001 04.08.09 M.Ichijo New A-79700E
EDIT
DATE
DESIG.
DESCRIPTION
33/97
TITLE
DRAW.NO.
SHEET
CUST.
TITLE
5.3 MESSAGE DATA
Difference of specification
Handling of message number and path number is difficult as follows.
In case of PMC-SB7
Message numbers Destination
CNC screen
Display
1000 to 1999 Alarm screen
(on path 1)
Alarm messages
- Path 1 is placed in the alarm state.
2000 to 2099 Operator messages
2100 to 2999
Operator
message screen
Operator messages (with no message
numbers)
- Only message data is displayed, and no
message number is displayed.
5000 to 5999 Alarm screen
(on path 2)
Alarm message
- Path 2 is placed in the alarm state.
- The displayed message number is a
specified number from which 4000 is
subtracted.
7000 to 7999 Alarm screen
(on path 3)
Alarm message
- Path 3 is placed in the alarm state.
- The displayed message number is a
specified number from which 6000 is
subtracted.
In case of PMC-SD7
Message
numbers
path Destination
CNC screen
Display
1000 to 1999 n Alarm screen
(on path n)
Alarm messages
- Path 1 is placed in the alarm state.
2000 to 2099 n Operator messages
2100 to 2999 n
Operator
message screen
(on path n)
Operator messages (with no message
numbers)
- Only message data is displayed, and no
message number is displayed.