B–64193EN/01
7. SERVO INTERFACE
107
The servo check connectors used with the Series 20i–B are not compatible
with the Series 20i–A. So, to connect the servo check board (board unit:
A16B–1600–0320) or interface board for automatic adjustment (board
unit: A16B–2300–0170 or A20B–2002–0810, Unit: A06B–6057–H620
or A06B–6057–H630) with the i Series, a new servo check adapter (board
unit: A20B–1007–0790) and special cable (A660–2042–T237#100R0)
are required. (The ordering information for the servo check adapter and
cable is A02B–0281–K822.)
Examples of connection
When the servo check board is used
Connect TEST0–3 with CN2 of the servo check board via the currently
used flat cable.
CA69
CNC
CN0
TESTn
CN2
Servo check adapter Servo check board
When the interface board for automatic adjustment is used
A) Connect TEST0–3 with CIN1/2 of the interface board for automatic
adjustment via a currently used flat cable.
CA69
CNC
CN0
TESTn
CIN1
Interface board for
automatic adjustment
CIN2
Servo check adapter
B) Connect TESTA/B with CIN3 of the interface board for automatic
adjustment via a straight cable (such as A660–2042–T007#*****).
CA69
CNC
CN0
TESTx
CIN3
Interface board for
automatic adjustment
Servo check adapter
NOTE
In any case, use the special cable (A660–2042–T237) to
connect CN0 with CA69 on the mother board of the CNC.
7.1.13
Connecting the Servo
Check Adapter