B–64193EN/01
5. CONNECTION TO CNC PERIPHERALS
81
Many cables without a shield (UTP cables) are commercially available as
twisted pair cables conforming to 10BASE–T or 100BASE–TX. To
improve noise immunity in factory automation environments, however,
be sure to use twisted pair cables (STP cables) with a common shield in
category 5.
Recommended cables (for fixed parts)
Manufacturer Specification Remark
Furukawa Electric Co., Ltd. DTS5087C–4P Twisted wires
Nissei Electric Co., Ltd. F–4PFWMF Single–wire cable
NOTE
No cable recommended for use in fixed sections shall be
used in movable sections. Be sure to use the following
movable–section cables.
Recommended cable (for movable sections)
Manufacturer Specification Remark
Oki Electric Cable
Co., Ltd.
AWG26 4P TPMC–C5–F(SB) Dedicated to FANUC products
Cable specification (FANUC original product, with no connector)
Drawing number: A66L–0001–0453
Manufacturer: Oki Electric Cable Co., Ltd.
Specification
– Electrical characteristic: Complying with EIA/TIA 568A
categories 3 and 5
The length of the cable to the hub must be kept within 50 m
because of its attenuation performance.
– Structure: Common–shield braided cable with drain wire
The conductors of the cable are AWG26 annealed–copper
strand wire, with a sheath 0.8 mm thick and an outer diameter
of 6.7"0.3 mm
– Fire resistance: UL1581 VW–1
– Oil resistance: As per FANUC’s internal standard (Equivalent
to conventional oil–resistant electrical cable)
– Flex resistance: Million or more bending cycles with a bending
radius of 50 mm (U–shaped bend test)
– UL style No.: AWM20276 (80_C/30V/VW–1)
NOTE
Use the TM21CP–88P(03) connector made by Hirose
Electric Co., Ltd. to this cable.
Cable Wires