B–63835EN/03
4.INTERFACE BETWEEN CNC AND PMC
305
1) DATA TABLE SETTING screen (C. DATA)
INITNO.SRHG.CONTG.DATA[]
NO. ADDRESS PARAMETER TYPE NO.OF DATA
001 D0000 00000000 0 10
002 D0020 00000011 1 20
003
004
005
006
007
008
PMC DATA TBL CONTROL #001
GROUP TABLE COUNT = 2
[][][][]
MONIT RUN
Number of
data table
group
Number of
data of
each data
table
Data length
Table
parameter
Head
address of
data table
(a) [G.DATA] soft key : Select the data display screen of data table.
(b)
No. of group [G.CONT] : Set the number of group for data table.
(c)
No. of group [NO.SRH] : Move the cursor to specified group.
(d)[INIT] soft key : Initialize of data table setting.
No. of group is 1, ADDRESS is D0000,
PARAMETER is 00000000, TYPE is 0, NO. OF
DATA is 1860.
ƠTable parameterơ
0 : Binary format
1 : BCD format
Protection of input data,
0 : not provided.
1 : provided.
0 : Displayed in binary or BCD (bit 0 is enabled)
1 : Displayed in hexadecimal (bit 0 is disabled)
#7 #6 #5 #4 #3 #2 #1 #0
ƠTYPEơ
0 : 1byte
1 : 2bytes
2 : 4bytes
4.3.4.5
Data table screen (DATA)