B–63835EN/03
6. DIGITAL SERVO
403
1) Amplifier setting screen
AMPLIFIER SETTING O1000 N00001
NO. AMP SERIES UNIT CUR. AXIS NAME
1A1–L α SVM–HV 40AL 1 X
2A1–M α SVM 12A 2 Y
3A2–L β SVM 40A 3 Z
4A3–L α SVM 20A 4 A
NO. EXTRA TYPE PCB ID
5 M1 A 0000 DETECTOR(8AXES)
6 M2 B 12AB
>_
MDI **** *** *** 13:11:56
[SETTING][ ][ READ ][ ][ INPUT ]
The amplifier setting screen displays the following items:
D NO. (controlled axis number)
For this item, enter a value of between 1 and the maximum number of
controlled axes. If a number that falls outside this range is entered, the
warning message “INVALID FORMAT” appears. If the entered
controlled axis number is duplicate or 0, the warning message
“SPECIFIED DATA IS OUT OF RANGE” appears when soft key
[SET] is pressed to assert the entered value. In this case, no value can
be entered for the parameter.
2) Axis setting screen
AXIS SETTING O1000 N00001
AXIS NAME AMP M1 M2 1–DSF Cs TNDM
1XA1–L 0 00 00
2YA1–M 1 0 1 0 0
3ZA2–L 0 0 0 1 0
4AA3–L 0 0 0 0 0
>_
MDI **** *** *** 13:11:56
[SETTING][ ][ READ ][ ][ INPUT ]
On the axis setting screen, the following items can be specified:
D M1 (connector number for pulse module 1)
For an axis that uses pulse module 1, enter a connector number using
a number in the range of between 1 and the maximum number of axes
for pulse module 1. When pulse module 1 need not be used, enter 0.
If a number that falls outside the valid range is entered, the warning
message “INVALID FORMAT” is displayed.