B–63835EN/03
4.INTERFACE BETWEEN CNC AND PMC
333
#7 DTBLDSP 0 : The PMC parameter data table control screen is displayed.
1 : The PMC parameter data table control screen is not displayed.
#7
IGNDINTK901
#6
EDITLAD
#5
CHKPRTY
#4
CALCPRTY
#3
TRNSRAM
#2
TRGSTAT
#1
DBGSTAT
#0
IGNKEY
#0 IGNKEY 0 : Function keys are enabled for a user program on the user screen.
1 : Function keys are disabled for a user program on the user screen.
* This flag is useful when a user program is used. When this bit is set
to 1, the user screen cannot be switched to the NC screen by using the
function keys. Program which invariably sets this bit to 0, or which
switches the user screen to the NC screen, must be prepared.
#1 DBGSTAT 0 : The C language debug function does not start automatic break
processing at power on.
1 : The C language debug function starts automatic break processing at
power on.
* This flag is useful when a user program is used.
#2 TRGSTAT 0 : The trigger stop function does not automatically start at power on.
1 : The trigger stop function starts automatically at power on.
#3 TRNSRAM 0 : After on–line editing, the ladder program is not automatically
transferred to the backup RAM.
1 : After on–line editing, the ladder program is automatically transferred
to the backup RAM.
#4 CALCPRTY 0 : A RAM parity calculation is made with the built–in programmer
function.
1 : No RAM parity calculation is made with the built–in programmer
function.
#5 CHKPRTY 0 : The system ROM and program ROM/RAM are checked for parity
errors.
1 : The system ROM and program ROM/RAM are not checked for parity
errors.
#6 EDITLAD 0 : The editing of a sequence program is disabled.
1 : The editing of a sequence program is enabled.
#7 IGNDINT 0 : The system initializes the LCD when the screen is switched to the
PMCMDI screen.
1 : The system does not initialize the LCD when the screen is switched to
the PMCMDI screen.
* This flag is useful when a user program is used. When the screen is
switched to the PMCMDI screen, PMC control software determines
whether the system initialize the LCD, by checking this flag. When
this flag is on, an application program must initialize the LCD.