B–63835EN/03
6. DIGITAL SERVO
401
D M1 (connector number for pulse module 1)
This item is the number of the connector for pulse module 1, specified
in parameter No. 1931.
D M2 (connector number for pulse module 2)
This item is the number of the connector for pulse module 2, specified
in parameter No. 1932.
D 1–DSF
This item is the value specified in bit 0 (parameter 1 DSP) of parameter
No. 1904. It is 1 for an axis (such as a high–speed current loop axis,
or high–speed interface axis) that exclusively uses a DSP, which is
usually shared by two–axes.
D Cs: Cs contour controlled axis
This item is the value specified in parameter No. 1933. It is 1 for the
Cs contour controlled axis.
3) Amplifier maintenance screen
The amplifier maintenance screen displays maintenance information
for servo amplifiers. This screen consists of the following two pages,
either of which can be selected by pressing the
or key.
AMPLIFIER MAINTENANCE O1000 N00001
AXIS NAME AMP SERIES UNIT AXES CUR.
1XA1–L α SVM–HV 2 40AL
2YA1–M α SVM 2 12A
3ZA2–L β SVM 1 40A
4AA3–L α SVM 1 20A
MDI **** *** *** 13:11:56
[ AMP ][ AXIS ][ MAINTE ][ ][ ]
AMPLIFIER MAINTENANCE O1000 N00001
AXIS NAME EDITION TEST MAINTE–NO.
1 X 01A 020123 01
2 Y 01A 020123 01
3 Z 01A 020123 01
4 A 02B 020123 01
MDI **** *** *** 13:11:56
[ AMP ][ AXIS ][ MAINTE ][ ][ ]