RFSx
RF2x
#5
1818
#6
#7 #4 #3 #2 #1 #0
Data type : Bit axis type
RFSx When the conditions are as follows, the axis moves until the
reference position is established and :
09
09
09
09
09
09
09
09
09
09
09
09
09
09
0 : the axis moves to the reference point.
1 : sequence complete without moving to the reference point.
(Conditions)
- Reference position is not established (ZRFn=0).
- G28 is commanded.
RF2x When the conditions are as follows,
0 : the axis moves to the reference point.
1 : sequence complete without moving to intermediate position or
reference position.
(Conditions)
- Reference position is established (ZRFn=1).
- G28 is commanded.
DATx
#5
1819
#6
#7 #4 #3 #2 #1 #0
Data type : Bit axis type
DATx When a manual reference point return is executed, an automatic
setting of parameter No.1883,1884 is
06
06
06
06
06
06
06
06
06
06
06
06
06
06
0 : Not executed.
1 : Executed.
The procedure of the automatic setting are following :
(1) Set a correct value to parameter No.1815,1821,1882.
(2) Positioning the axis to reference position by mechanical
measurement by manual operation.
(3) Set parameter No.1819#2 to ‘1’.
(4) Execute manual reference point return.
When the manual reference point return is finished, parameter
No.1883,1884 are set and No.1819#2 is turn to ‘0’.
10/15
A- 61209EN
DRAW.No.
FANUC Series 16/18-MB/TB/MC/TC
FANUC Series 16i/18i/21i-MA/TA/MB/TB
Specifications of Distance Coded
Linear Scale Interface
Title
Descriptions of products are altered.
Straightness compensation is supported.
First edition
DESCRIPTION
A.Fukumoto
A.Fukumoto
DESIGNE
02.09.24
00.06.20
95.11.14
DATE
13
12
01
EDIT.
T.Endo
H.Kochiya