(6) A difference of parameter No.1821 and No.1882 must be more than 4.
08
08
08
08
08
08
08
08
08
08
08
08
08
08
08
08
Example)
When the scale, which is that mark1 interval is 20.000mm and mark2 interval is
20.004mm, is used on IS-B machine :
When the detection unit of 0.001mm is selected, parameter No.1821 and No.1882
must be set "20000" and "20004", and the difference of them is "4".
To use such a scale, please adjust the detection unit by modification of parameter
No.1820(CMR) and No.2084/2085(flexible feed gear) to make the difference of
No.1821 and 1882 more than 4 as following examples.
(a) Set the detection unit=0.0001mm, and set No.1821=200000,No.1882=200040
(b) Set the detection unit=0.0005mm, and set No.1821=40000,No.1882=40008
Note) When the detection unit is changed, all of parameters which are concerned
with the detection unit (e.g. in-position width, positioning deviation limit,
etc.) must be changed.
(7) There are the following limitations when the angular axis control is used.
10
10
10
10
10
10
10
10
10
10
10
(a) It is necessary to use the linear scale with the distance coded reference mark
for both the perpendicular axis and the angular axis.
(b) When the reference point of the perpendicular axis is established, it is
necessary to establish the reference point of the angular axis previously. When
the reference point of the angular axis is not previously established, the P/S090
alarm is generated.
(c) During the reference point establishment operation of the angular axis, the
command in the perpendicular axis is invalid in the manual reference point
return.
* The angular axis control is supported for only i series
model-A(B1F2,B1FB,B1F4 series) and i series model-B(all series).
(8) Measurement of two point (parameter No.1802#2(DC2)=1)
11
11
11
11
11
11
11
11
11
11
11
13
13
(a) Please set the direction of the scale zero point in the parameter (No.1817#4
(SCP)) correctly at two point measurement. Because an incorrect coordinate
system will be established when a wrong value is set in parameter SCP. It is
very dangerous. In this case, please execute reference point return again after
setting the correct value in parameter SCP.
(b) Because an incorrect value is set in parameter No.1883 and 1884 when setting
parameter SCP is incorrect when the automatic setting of parameter No.1883
and 1884 was executed. It is very dangerous. In this case, please execute
automatic setting of parameter No.1883 and 1884 again after setting the
correct value in parameter SCP.
7/15
A- 61209EN
DRAW.No.
FANUC Series 16/18-MB/TB/MC/TC
FANUC Series 16i/18i/21i-MA/TA/MB/TB
Specifications of Distance Coded
Linear Scale Interface
Title
Descriptions of products are altered.
Straightness compensation is supported.
First edition
DESCRIPTION
A.Fukumoto
A.Fukumoto
DESIGNE
02.09.24
00.06.20
95.11.14
DATE
13
12
01
EDIT.
T.Endo
H.Kochiya
* The measurement of two point is supported for only i series
model-A(B0F2,B1F2,B0FB,B1FB,B0F4,B1F4 series) and i series model-B(all
series).