3. Parameters
OPTx
DCLx
DCRx
#5
1815
#6
#7 #4 #3 #2 #1 #0
Data type : Bit axis type
OPTx Position detector
0 : A separate pulse coder is not used.
1 : A separate pulse coder is used.
(When a distance coded linear scale use, set "1".)
DCLx Separate pulse coder
0 : A distance coded linear scale is not used.
1 : A distance coded linear scale is used.
DCRx Distance coded pulse coder
07
07
07
07
0 : A distance coded rotary encoder is not used.
1 : A distance coded rotary encoder is used.
(Note) Please set a parameter DCL to “1”, too.
DC4 DC2
#5
1802
#6
#7 #4 #3 #2 #1 #0
Data type : Bit type
DC4 When the reference point is established by the distance coded linear
scale,
0 : The axis moves until three reference marks are detected.
1 : The axis moves until four reference marks are detected.
DC2 When the reference point is established by the distance coded linear
scale,
11
11
11
11
11
11
11
11
11
0 : The axis moving depends on the setting of the parameterDC4.
1 : The axis moves until two reference marks are detected.
Note
1) When this parameter is set to 1, set the direction of scale zero in the
parameter (No.1817#4(SCP)) correctly.
2) Even if DC2 is "1", the rotary axis(parameter1815#3(DCR)=1)
follows DC4.
9/15
A- 61209EN
DRAW.No.
FANUC Series 16/18-MB/TB/MC/TC
FANUC Series 16i/18i/21i-MA/TA/MB/TB
Specifications of Distance Coded
Linear Scale Interface
Title
Descriptions of products are altered.
Straightness compensation is supported.
First edition
DESCRIPTION
A.Fukumoto
A.Fukumoto
DESIGNE
02.09.24
00.06.20
95.11.14
DATE
13
12
01
EDIT.
T.Endo
H.Kochiya