2002/08/09 T.Inagaki E.Genma
1821 Reference counter size for each axis
[Data type] 2-word axis
[Unit of data] Detection unit
[Data range] 0 to 99999999
Sets the intervals of mark 1 of the linear scale with abssolute addressing
referenced marks.
Caution
On the linear scale with distance-coded reference marks (A/B phase),
this parameter is used on the usual purpose. (Setting reference counter
size foreach axis)
1882 Space between mark-2 indications on the linear scale with absolute
addressing reference marks
[Data type] 2-word axis
[Unit of data] Detection unit
[Data range] 0 to 99999999
Sets the intervals of mark 1 of the linear scale with abssolute addressing
referenced marks.
Caution
This parameter is unavailable on linear scale with distance-coded
reference marks (serial).
A-78754EN
FANUC Series 16i/18i/21i –B, 0i –B/C
Linear scale I/F with absolute address referenced
mark / Distance coded scale
Drawing No.
Page
Descri
tionDate Edit
21/32
03 2004/11/30 T,Inagaki (3) is added or altered.
02 2002/11/18 T
Ina
aki
2
is added or altered. E.Genma
Title