2002/08/09 T.Inagaki E.Genma
【Synchronization compensation function】
(2)
By setting parameter 8301#7(in case that only one master/slave axis pair is in sync) or
8303#7(in case that more than one master/slave axis pair is in sync) is set to '1',
compensation pulses are outputted to the slave axis to adjust its position such that it agrees
with that of master axis. As a result, the difference between the positions of master axes and
slave axes are compensated automatically.
Note)
1. If the synchronization error exceeds the value of parameter 8315(in case that only one
master/slave axis pair is in sync) or 8325(in case that more than one master/slave axis
pair is in sync), servo alarm 407 occurs. This alarm can be cleared by the reset key. As
the position error for the slave axis remains even after the alarm is cleared, however, the
positions must be adjusted.
2. The synchronization compensation function is not executed when the servo alarm is
eliminated.
3. In case that more than one master/slave axis pair is in sync, 8303#7(bit axis type) should
be set on the master axis side.
2.3 Reference Position Return
(1) When the reference position is not established and the axis moved by turning the
feed axis direction signal (+J1,-J1,+J2,-J2,...) to “1” in REF mode, the reference
position establishment procedure is executed.
(2) When the reference position is already established and the axis is moved by turning
the feed axis direction signal (+J1,-J1,+J2,-J2,...) to “1” in REF mode, the axis is
moved to the reference point without executing the reference position establishment
procedure.
(3) When the reference position is not established and the reference position return
command (G28) is executed, the reference position establishment procedure is
executed. The next movement the axis depends on the setting of PRM
No.1818#0(RFS).
(4) When the reference position is already established and the reference position
command (G28) is executed, the movement of the axis depends on the setting of PRM
No.1818#1(RF2).
A-78754EN
FANUC Series 16i/18i/21i –B, 0i –B/C
Linear scale I/F with absolute address referenced
mark / Distance coded scale
Drawing No.
Page
Descri
tionDate Edit
6/32
03 2004/11/30 T,Inagaki (3) is added or altered.
02 2002/11/18 T
Ina
aki
2
is added or altered. E.Genma
Title