2002/08/09 T.Inagaki E.Genma
5. Alarm
Number
Message Contents
090
REFERENCE RETURN INCOMPLETE
In case of Linear scale I/F with absolute
address referenced mark (A/B phase), the
actual interval of reference marks is
different from parameter (No.1821,1882)
setting value.
5220
REFERENCE POINT ADJUSTMENT
MODE
In case of Linear scale I/F with absolute
address referenced mark (A/B phase) or
Linear scale with distance-coded reference
marks (serial), the reference point auto
setting parameter (No.1819#2) is set to “1”.
Move the machine to reference position by
manual operation and execute manual
reference return.
5325
SERIAL DCL:FOLLOW-UP ERROR
1. The amount of follow-up is more than
2147483647 or less than –2147483648
on detection unit. To reduce the
follow-up amount, please adjust the
point that we begin follow-up.
2. The value of parameter No.1884 is out
of range.
5326
SERIAL DCL:REF-POS ESTABLISH ERR
The amount of movement for establish
reference position was exceeded the
amount of parameter 14010. Please try
again or change parameter 14010 larger.
5327
SERIAL DCL:MISMATCH (SSYNC CTRL)
Master/slave axes of simple synchronized
control, one of them is the linear scale with
distance-coded reference marks (serial),
and the other of them is not the linear
scale with distance-coded reference marks
(serial). Please establish reference position
with the input signal SYNCJn<g140>
setting to zero.
5328
SERIAL DCL:MISMATCH (ANGL-AXIS)
On angular axis control, one of the
angular/perpendicular axes is the scale
with ref-pos, and the other of them is not
the scale with ref-pos. Such system is not
admired.
(2)
(*)P/S alarm 5325-5328 is generated only on Linear scale with distance-coded reference marks (serial)
A-78754EN
FANUC Series 16i/18i/21i –B, 0i –B/C
Linear scale I/F with absolute address referenced
mark / Distance coded scale
Drawing No.
Page
Descri
tionDate Edit
32/32
03 2004/11/30 T,Inagaki (3) is added or altered.
02 2002/11/18 T
Ina
aki
2
is added or altered. E.Genma
Title