2002/08/09 T.Inagaki E.Genma
#7 #6 #5 #4 #3 #2 #1 #0
1817 SCPx
[Data type] Bit axis
SCPx If DC2x (Paramete No.1802#2) is set to '1', the scale-zero point of the linear
scale with absolute addressing referenced mark is:
0: On the negative direction side. (Viewed from the scale zero point, the
reference position is on the positive direction side.)
1: On the positive direction side. (Viewed from the scale zero point, the
reference position is on the negative direction side.)
Caution
1. An incorrect coordinate system will be established when a wrong value
is set in this parameter. In such a case, please execute reference point
return again after setting the correct value in this parameter.
2. This parameter is unavailable on linear scale with distance-coded
reference marks (serial)
[ Example ]
When the parameter SCP is set to "0",
Title
When the parameter SCP is set to "1",
+
-
Reference point
Machine coordinate system
M2 M1
M1 M2 M1 M2
M1
9.940 9.960 9.980
0.020
Scale zero
0.040
+
-
Reference point
Machine coordinate system
0.020
Scale zero
0.040
Mark1=Mark2
M2 M1 M1 M2 M1
M1 M2 M1 M2
M1
9.980 9.960 9.940
Mark1=Mark2
M1 M2 M1