(6) A difference of parameter No.1821 and No.1882 must be more than 4.
Example)
When the scale, which is that mark1 interval is 20.000mm and mark2 interval is
20.004mm, is used on IS-B machine :
When the detection unit of 0.001mm is selected, parameter No.1821 and No.1882 must
be set "20000" and "20004", and the difference of them is "4".
To use such a scale, please adjust the detection unit by modification of parameter
No.1820(CMR) and No.2084/2085(flexible feed gear) to make the difference of No.1821
and 1882 more than 4 as following examples.
(a) Set the detection unit=0.0001mm, and set No.1821=200000,No.1882=200040
(b) Set the detection unit=0.0005mm, and set No.1821=40000,No.1882=40008
Note) When the detection unit is changed, all of parameters which are concerned with
the detection unit (e.g. in-position width, positioning deviation limit, etc.) must
be changed.
(7) There are the following limitations when the angular axis control is used.
(a) It is necessary to use the linear scale I/F with absolute address referenced mark (A/B
phase) for both the perpendicular axis and the angular axis.
(b) When the reference point of the perpendicular axis is established, it is necessary to
establish the reference point of the angular axis previously. When the reference point
of the angular axis is not previously established, the P/S090 alarm is generated.
(c) During the reference point establishment operation of the angular axis, the
command in the perpendicular axis is invalid in the manual reference point return.
A-78754EN
FANUC Series 16i/18i/21i –B, 0i –B/C
Linear scale I/F with absolute address referenced
mark / Distance coded scale
Drawing No.
Page
Descri
tionDate Edit
9/32
03 2004/11/30 T,Inagaki (3) is added or altered.
02 2002/11/18 T
Ina
aki
2
is added or altered. E.Genma
Title