B--63005EN/02
1. DISPLAY AND OPERATION
103
NOTE
For the 20i, memory all clear operation based on (7) and (9)
is also effective.
Manual operation
Function
KEY
SW
PWE
=1
Mode
Func-
tion key
Operation
Manual refer-
ence point
return
JOG
Turn on Reference point return switch → Turn on +X, --X, +Z, or --Z →
Reference point return switch LED lit.
Jog feed JOG
Turn on +X, --X, +Z, or --Z → Use JOG FEEDRATE to set jog feedrate
→ Press Rapid traverse button, if required.
Incremental
feed
INC
Use Move distance selection switch to select move distance → Turn on
+X, --X, +Z, or --Z → Press Rapid traverse button, if required.
Manual
handle feed
HND
Use Axis selection switch to select axis to be operated → Use Handle
magnification selection to select magnification → Turn manual pulse
generator.
Display
Function KEY
SW
PWE
=1
Mode
Func-
tion key
Operation
Amount of
program
memory in
use
EDIT
PROG
[DIR]
Command
Command value being executed, and previously specified modal value
va
ue
sp
ay
[CURRNT]
Command value being executed, and next command value to be
executed
[ NEXT ]
MEM
or
PROG
Command value entered from MDI, and previously specified modal
value
[MDI]
Program in memory being executed
[PRGRM]
Executable blocks in memory and current position
[CHECK]