5. INPUT AND OUTPUT OF DATA
429
Parameters can be input and output using the ALL IO screen.
Inputting parameters
1 Press soft key [PARAM] on the ALL IO screen, described in Section
5.7.1.
2 Select EDIT mode.
3 Press soft key
[(OPRT)]. Soft keys change as shown below.
READ PUNCH
4 Press soft key [READ], then [EXEC].
The parameters are read, and the “INPUT” indicator blinks at the
lower--right corner of the screen. Upon the completion of input, the
“INPUT” indicator is cleared from the screen.
To cancel input, press soft key
[CAN].
Outputting parameters
1 Press soft key [PARAM] on the ALL IO screen, described in Section
5.7.1.
2 Select EDIT mode.
3 Press soft key
[(OPRT)]. Soft keys change as shown below.
READ PUNCH
4 Press soft key [PUNCH], then [EXEC].
The parameters are output, and the “OUTPUT” indicator blinks at the
lower--right corner of the screen. Upon the completion of output, the
“OUTPUT” indicator is cleared from the screen.
To cancel output, press soft key
[CAN].
5.7.3
Inputting and
Outputting Parameters
Procedure
EXECCAN
Procedure