9. TROUBLESHOOTING
B--63005EN/02
624
These alarms are issued if any of the axis control cards and the slaves
(such as servo amplifiers) and optical cables connected to the FSSB is
defective.
No. Message Description
5134 FSSB: OPEN READY TIME
OUT
The FSSB did not become ready to
open during initialization.
5135 FSSB: ERROR MODE The FSSB entered an error mode.
5137 FSSB: CONFIGURATION
ERROR
The FSSB detected a configuration er-
ror.
5197 FSSB: OPEN TIME OUT The FSSB did not open when the CNC
had allowed the FSSB to open.
5198 FSSB: ID DATA NOT READ The initial ID information for the amplifi-
er cannot be read because of a failure
in the temporary assignment.
The processing of the FSSB at power on is as described below:
1 The CNC initializes the FSSB and the servo.
2 The servo returns the first ready signal.
3 The first ITP interrupt is generated.
4 The CNC waits for the FSSB to become ready to open.
5 The CNC checks that the FSSB did not detect a configuration error.
6 The CNC allows the FSSB to open.
7 The CNC checks that the FSSB has opened.
8 The servo returns the second ready signal.
9 Normal operation
9.22
ALARM 5134
(FSSB: OPEN
READY TIME OUT)
ALARM 5135 (FSSB:
ERROR MODE)
ALARM 5137 (FSSB:
CONFIGURATION
ERROR)
ALARM 5197 (FSSB:
OPEN TIME OUT)
ALARM 5198 (FSSB:
ID DATA NOT READ)
Causes and actions
D Processing of the FSSB
at power on