7. DIGITAL SERVO
B--63005EN/02
530
D TWO--AXES
This item is the value specified in bit 0 (parameter 1 DSP) of parameter
No. 1904. It is 1 for an axis (such as a learningcontrol axis, high--speed
current loop axis, or high--speed interface axis) that exclusively uses
a DSP, which is usually shared by two--axes.
D Cs: Cs contour controlled axis
This item is the value specified in parameter No. 1933. It is 1 for the
Cs contour controlled axis.
D TANDEM (M series only)
This item is the number specified in parameter No. 1934. Consecutive
odd and even numbers are displayed for the master and slave axes for
tandem control.
3) Amplifier maintenance screen
The amplifier maintenance screen displays maintenance information
for servo amplifiers. This screen consists of the following two pages,
either of which can be selected by pressing the
or key.
AMPLIFIER MAINTENANCE O1000 N00001
AXIS NAME AMP SERIES UNIT AXES CUR.
1 X A1-L ∼ SVM-HV 2 40AL
2 Y A1-M ∼ SVM 2 12A
3 Z A2-L ϒ SVM 1 40A
4 A A3-L ∼ SVM 2 20A
5 B A3-M ∼ SVM 2 40A
6 C A4-L ∼ SVU 1 240A
MDI **** *** *** 13:11:56
[ AMP ][ AXIS ][ MAINTE ][ ][ ]
AMPLIFIER MAINTENANCE O1000 N00001
AXIS NAME EDITION TEST MAINTE-NO.
1 X 01A 970123 01
2 Y 01A 970123 01
3 Z 01A 970123 01
4 A 02B 970123 01
5 B 02B 970123 01
6 C 02B 970123 01
MDI **** *** *** 13:11:56