6. INTERFACE BETWEEN CNC AND PMC
B--63005EN/02
472
#7
K018
#6 #5 #4 #3 #2 #1 #0
(K901 for SB6)
#7(IGNDINT) 0: When the screen is switched to the PCMMDI screen, the screen is
initialized.
1: When the screen is switched to the PCMMDI screen, the screen is not
initialized.
*It is effective for PMC--SC3/SC4
#5(CHKPRTY)
0: The parity check is performed for the system ROM and program
ROM/RAM.
1: The parity check is not performed for the system ROM and program
ROM/RAM.
#4(CALCPRTY)
0: The built--in programmer function performs RAM parity calculation.
1: The built--in programmer function does not perform RAM parity
calculation.
#3(TRNSRAM)
0: A ladder program is not automatically sent to the backup RAM after
on--line editing is completed.
1: A ladder program is automatically sent to the backup RAM after on--line
editing is completed.
#2(TRGSTAT)
0: The trigger stop function does not automatically start when the power is
turned on.
1: The trigger stop function automatically starts when the power is turned on.
#1(DBGSTAT) 0: In the C language debug function, the automatic break processing
does not start when the power is turned on.
1 : In the C language debug function, the automatic break processing
starts when the power is turned on.
*This flag is effective for the PMC--SC3/SC4.
#0(IGNKEY) 0 : Function keys are enabled when a user program displays the user
screen.
1 : Function keys are disabled when a user program displays the user
screen.
*This flag is effective for the PMC--SC3/SC4.
When this bit is set to 1 of the user screen, the screen cannot be switch to
the NC screen using function keys. A program which always sets this bit
to 0 or which changes the screen to the NC screen is required.
#7
K019
#6 #5 #4 #3 #2 #1 #0
(K902 for SB6)
#1(C--REJECT) 0 : A C--language program is activated.
1 : A C--language program is forcibly activated.
*The flag is effective for the PMC--SC3/SC4.
These bits are status of not used for PMC management software are used
by system. Do not change the values.
Usually all the bits are 0.