2
01.05.24
18/41
Descri
tion
Design.
DateEd
01.03.23
SHEET
DRAW. No.
CUST.
TITLE
okota
okota
Newly designed
i series Spindle
Start-up Procedure
-53866E-387/02
FANUC LTD
1
5. Parameters related to normal operation mode
5.1 List of parameters related to normal operation mode
Parameter No.
0 15
1st 2nd 1st 2nd
15i
16i
16
Description
6540 6680 3040 3180 3040 4040 Velocity loop proportional gain for normal operation
(HIGH) CTH1A=0
6541 6681 3041 3181 3041 4041 Velocity loop proportional gain for normal operation
(LOW) CTH1A=1
6548 6688 3048 3188 3048 4048 Velocity loop integral gain for normal operation (HIGH)
CTH1A=0
6549 6689 3049 3189 3049 4049 Velocity loop integral gain for normal operation (LOW)
CTH1A=1
6582 6722 3082 3222 3082 4082 Setting the acceleration/deceleration time
6583 6723 3083 3223 3083 4083 Motor voltage setting for normal rotation
6900 6940 3280 3500 3136 4136 Motor voltage setting for normal rotation (for low-speed
characteristics in speed range switching control)
5.2 Details of parameters related to normal operation mode
0 15
15i 16i/16
1st 6540 3040 3040 4040
Velocity loop proportional gain for normal operation (HIGH) CTH1A=0
2nd 6680 3180
0 15
15i 16i/16
1st 6541 3041 3041 4041
Velocity loop proportional gain for normal operation (LOW) CTH1A=1
2nd 6681 3181
Data unit :
Data range : 0 to 32767
Standard setting : 10
This data is used to set the velocity loop proportional gain for normal
operation. A parameter is selected with the CTH1A input signal.
0 15
15i 16i/16
1st 6548 3048 3048 4048
Velocity loop integral gain for normal operation (HIGH) CTH1A=0
2nd 6688 3188