2
01.05.24
2/41
Descri
tion
Design.
DateEd
01.03.23
SHEET
DRAW. No.
CUST.
TITLE
okota
okota
Newly designed
i series Spindle
Start-up Procedure
-53866E-387/02
FANUC LTD
1
1. Overview
This manual mainly describes the spindle parameters when you use αi
series spindle amplifiers and start-up the spindle.
In αi series spindle, please attention that parameter specifications related
to detectors are different from α series.
Parameters and adjustment method are the same as α series for each
function (operation mode), orientation, rigid tapping, Cs contouring control,
spindle synchronization control etc.
Regarding parameters for each motor model of αi series spindle motor, see
table of parameters informed separately.
αi series spindle motor amplifier does not support the following functions
now.
Orientation in spindle synchronization mode
Spindle switching control
Spindle differential speed control
Spindle EGB
Spindle tandem control
Operation mode function by check board
Magnetic sensor method spindle orientation (This function is not supported.
Please use orientation with external reference switch or orientation with
separate BZi sensor.)
Minimum time orientation (This function is abolished so use high speed
orientation function.)