Indica
tion
Status error Action
01 SFR (normal rotation command), SRV (reverse rotaion
command) or ORCM (orientation command) is entered
when *ESP (emergency stop signal, which
may be a input signal or contact signal) and MRDY
(machine ready signal) are not applied.
Check the sequence of *ESP and MRDY. For
MRDY, check bit 0 of parameter No.4001,
Specifying whether to use the MRDY signal.
03 The Cs contouring control command is input although
parameter No. 4002 bits 3,2,1 and 0 are set to all 0 to
specify that position sensor is nothing (position control
does not perform). In such a case, the motor is not
activated.
Check the parameter setting.
04 The servo mode (rigid tapping, spindle positioning etc)
or
spindle synchronization command is input although
parameter No. 4002 bits 3,2,1 and 0 are set to all
0 to specify that position sensor is nothing (position
control does not perform). In such a case, the motor is
not activated.
Check the parameter setting.
05 When the option parameter of the orientation function is
not set, ORCM (orientation command) is entered.
Check the parameter setting enabling the use of
the orientation function.
06 When the option parameter of the speed range
switching
control function is not set, winding for low-speed
characteristics is selected (with RCH=1).
Check the setting of the parameter for using the
speed range switching control function, and the
power line status check signal (RCH).
07 When the Cs contouring control command is entered,
neither SFR (normal rotation command) nor SRV
(reverse rotation command) is entered.
Check the sequence.
08 When the servo mode (rigid tapping, spindle positioning
etc) control command is entered, neither SFR (normal
rotation command) nor SRV (reverse rotation command)
is entered.
Check the sequence.
09 When the spindle synchoronization control command is
entered, neither SFR (normal rotation command) nor
SRV (reverse rotation command)is entered.
Check the sequence.
10 When the Cs contouring control command is active, and
another mode (such as the servo mode, spindle
synchronous control, and orientation) is specified.
When Cs contouring contorl is specified, do not
specify another mode. To enter another mode,
first cancel the Cs contouring contorl command.