2
01.05.24
6/41
Descri
tion
Design.
DateEd
01.03.23
SHEET
DRAW. No.
CUST.
TITLE
okota
okota
Newly designed
i series Spindle
Start-up Procedure
-53866E-387/02
FANUC LTD
1
3.3 Parameters related to spindle speed commands
Parameter No.
0T 0M 15
15i 16i/16
Description
0013
#7,6
- - 3706
#7,6
Spindle speed command polarity
(enabled when input signal SSIN is set to 0)
- 0543
(*1)
5618 3735
(M system)
Minimum clamp speed of spindle motor
- 0542
(*1)
5619 3736
(M system)
Maxmum clamp speed of spindle motor
6520 3020 3020 4020 Maxmum spindle motor speed
0539 0577 5613 5613 - Spindle speed command offset
(always set to 0)
0516 5614 5614 - Spindle speed command gain adjustment
(always set to 1000)
0540
~
0543
0541
0539
0555
(*2)
3741
to
3744
Maximum spindle speed corresponding to the
gear
Note
1. Supported for the M system only. These parameters are disabled,
when the constant surface speed control option is used.
2. When the constant surface speed control option is used with the M
system, the same parameter numbers as for the T system (No.0540
to 0543) are used.
4. Parameters related to detector
Note
In αi series spindle, please attention that parameters specification related to detector are differerent from α series