2
01.05.24
19/41
Descri
tion
Design.
DateEd
01.03.23
SHEET
DRAW. No.
CUST.
TITLE
okota
okota
Newly designed
i series Spindle
Start-up Procedure
-53866E-387/02
FANUC LTD
1
0 15
15i 16i/16
1st 6549 3049 3049 4049
Velocity loop integral gain for normal operation (LOW) CTH1A=1
2nd 6689 3189
Data unit :
Data range : 0 to 32767
Standard setting : 10
This data is used to set the velocity loop integral gain for normal operation.
A parameter is selected with the CTH1A input signal.
0 15
15i 16i/16
1st 6583 3083 3083 4083
Motor voltage setting for normal rotation
2nd 6723 3223
0 15
15i 16i/16
1st 6900 3280 3136 4136
Motor voltage setting for normal rotation (for low-speed characteristics in
speed range switching control)
2nd 6940 3500
Data unit : 1%
Data range : 0 to 100
Standrad setting : Depends on the motor model
This parameter is used to set a motor voltage in normal operation. The
motor voltage to be set depends on the motor model, the most usual setting
is 30.
6. Spindle parameter table
Spindle parameters are classified into the following types:
A : Parameters related to detectors
B : Parameters related to various functions (operating modes)
C : Parameters for driving of spindle motor
(Set parameters for each motor model)
D : Parameters related to alarm detection conditions