2
01.05.24
40/41
Descri
tion
Design.
DateEd
01.03.23
SHEET
DRAW. No.
CUST.
TITLE
okota
okota
Newly designed
i series Spindle
Start-up Procedure
-53866E-387/02
FANUC LTD
1
Indica
tion
Status error Action
11 When the servo mode control command (rigid tapping,
spindle positioning, etc) is active, and another mode
(such as Cs contouring control, spindle synchronization
control, and orientation) is specified.
When a servo mode is specified, do not specify
another mode. To enter another mode, first
cancel the servo mode command.
12 When the spindle synchronization control command is
active, and another mode (Cs contouring control, servo
mode, or orientation) is specified.
When spindle synchronization control is
specified,
do not specify another mode. To enter another
mode, first cancel the spindle synchronization
control command.
13 When the orientation command is active, and another
mode (Cs contouring contorl, servo mode, or spindle
synchronization control ) is specified.
When orientation is specified, do not specify
another mode. To enter another mode, first
cancel the orientation command.
14 SFR (normal rotation command) and SRV (reverse
rotation command) are entered at the same time.
Specify only SFR or SRV at one time.
15 When parameter No.4000 bit 5 is set to 1 to specify
the use of the differential speed control function, the Cs
contouring control command is entered.
Check the parameter setting and input signal.
16 When parameter No.4000 bit 5 is set to 0 to specify
that the differential speed control function is not used,
DEFMD (differential speed mode command) is entered.
Check the parameter setting and the differential
speed mode command.
17 The setting of parameter No. 4011 bits 2, 1, and 0 for
specifying a speed detector is incorrect. The specified
speed detector cannot be found.
Check the parameter setting.
18 When parameter No. 4002 bits 3, 2, 1 and 0 is set to
all 0 to specify that position sensor is nothing (position
control does not perform), Orientation by a position
coder is specified.
Check the parameter setting and input signal.
19 When orientation by a magnetic sensor is active, and
another mode (Cs contouring control, servo mode, or
spindle synchoronization control) is specified.
When orientation is specified, do not specify
another mode. To enter another mode, first
cancel the orientation command.
24 In continuous indexing with orientation by a position
coder, incremental operation (INCMD=1) is first
performed, after which the absolute position command
(INCMD=0) is entered.
Check INCMD (incremental command). Before
specifying absolute position commands in
succession, perform absolute position command
orientation.
29 Parameters (No.4018#6=0, No.4320 to 4323 not equal
0) for minimum time orientation function are set.
In αi series spindle amplifier, minimum time
orientation function can not be used. Use the
other method orientation.