2
01.05.24
4/41
Descri
tion
Design.
DateEd
01.03.23
SHEET
DRAW. No.
CUST.
TITLE
okota
okota
Newly designed
i series Spindle
Start-up Procedure
-53866E-387/02
FANUC LTD
1
3. Setting parameters to start-up
3.1 Parameters for the αi series (Serial) spindle system.
Parameter No.
0 15
1st
spindle
2nd
spindle
1st
spindle
2nd
spindle
15i 16i/16
Description
-
(*1)
-
(*1)
5606
#0
5606
#1
5606
#0
-
(*1)
Whether to use αi series (Serial)
spindle amplifier
0071
#4
5604
#0
5841
(*2)
3701
#4
Number of αi series (Serial) spindle
amplifiers connected
Note
1. Optional parameter
2. For series 15i, specify an axis number in No.5841.
3.2 Automatic spindle parameter initialization
(1) Parameter list
Parameter No.
0 15
1st
spindle
2nd
spindle
1st
spindle
2nd
spindle
15i 16i/16
Description
6519
#7
6659
#7
5607
#0
5607
#1
5607
#0
4019
#7
Function for automatically
initializing
αi series (Serial) spindle
parameters
6633 6773 3133 3273 3133 4133 Motor model code
(2) Procedure for automatic spindle parameter initialization.
Perform automatic spindle parameter initialization by the following
procedure.
1. Set the model code for the desired motor for automatic parameter
initialization.
When there is no model code, set model code 300 (or 400 when the
speed range switching function is used) for automatic parameter
initialization, then manually change the parameter data according
to the parameter list for each model.