
2
01.05.24
27/41
Descri
tion
Design.
DateEd
01.03.23
SHEET
DRAW. No.
CUST.
TITLE
okota
okota
Newly designed
i series Spindle
Start-up Procedure
-53866E-387/02
FANUC LTD
1
FS0 FS15 Application
1st
spindle
2nd
spindle
1st
spindle
2nd
spindle
FS15i
FS16i
/16
Standard
Initial
Setting
data
Contents
MAIN
high
speed
MAIN
low
speed
SUB
high
speed
SUB
low
speed
Class-
Ificati-
on
Internal
data
number
F-xxx
6582 6722 3082 3222 3082 4082 10 Setting of acceleration/
deceleration time
Ο Ο
B 072
6583 6723 3083 3223 3083 4083 Depends
on the
model
Motor voltage during normal
rotation
Ο
B 073
6584 6724 3084 3224 3084 4084 Depends
on the
model
Motor voltage during
orientation
Ο Ο
B 074
6585 6725 3085 3225 3085 4085 Depends
on the
model
Motor voltage in servo
mode/during synchronization
control
Ο
B 075
6586 6726 3086 3226 3086 4086 Depends
on the
model
Motor voltage in Cs
contouring mode
Ο Ο
B 076
6587 6727 3087 3227 3087 4087 115 Overspeed level
Ο Ο
D 077
6588 6728 3088 3228 3088 4088 75 Level for detecting excess
velocity error when motor
is restrained
Ο Ο
D 078
6589 6729 3089 3229 3089 4089 200 Level for detecting excess
velocity error when motor
rotates
Ο Ο
D 079
6590 6730 3090 3230 3090 4090 90 Overload detection level
Ο Ο
D 080
6591 6731 3091 3231 3091 4091 100 Rate of change in position
gain during reference position
return in servo mode
Ο Ο
B 081
6592 6732 3092 3232 3092 4092 100 Rate of change in position
gain during reference position
return in Cs contouring control
mode
Ο Ο
B 082
6593 6733 3093 3233 3093 4093 Depends
on the
model
Value displayed on load
meter
at maximum output(low-speed
winding, FS15i,16i/16 only)
Ο
C 083
6594 6734 3094 3234 3094 4094 0 Disturbance torque
compensation constant
Ο Ο
B 084
6595 6735 3095 3235 3095 4095 0 Adjusted output voltage of
speed meter
Ο Ο
B 085
6596 6736 3096 3236 3096 4096 0 Adjusted output voltage of
load meter
Ο Ο
B 086
6597 6737 3097 3237 3097 4097 0 Feedback gain of spindle
speed
Ο Ο
B 087
6598 6738 3098 3238 3098 4098 0 Maximum speed of position
sensor signal detection
Ο Ο
A 088
6599 6739 3099 3239 3099 4099 0 Motor active delay
Ο Ο
B 089
6600 6740 3100 3240 3100 4100 Depends
on the
model
Base speed of motor output
Specifications
Ο
C 090
6601 6741 3101 3241 3101 4101 Depends
on the
model
Output limit for motor output
Specification
Ο
C 091
6602 6742 3102 3242 3102 4102 Depends
on the
model
Activating voltage saturation
speed at no load
Ο
C 092
6603 6743 3103 3243 3103 4103 Depends
on the
model
Base speed limit ratio
Ο
C 093
6604 6744 3104 3244 3104 4104 Depends
on the
model
Proportional gain of current
Loop
Ο
C 094
6605 6745 3105 3245 3105 4105 0 Reserved
Ο
C 095
6606 6746 3106 3246 3106 4106 Depends
on the
model
Integral gain of current loop
Ο
C 096
6607 6747 3107 3247 3107 4107 0 Reserved
Ο
C 097