4. DESCRIPTION OF PARAMETERS
B–63510EN/01
100
#7
3450
#6 #5 #4
NPS
#3
CQD
CQD
#2 #1 #0
AUP
[Data type] Bit
AUP When a command for the second miscellaneous function contains a
decimal point or negative sign:
0 : The command is invalid.
1 : The command is valid.
NOTE
For the T series, a decimal point and negative sign are
supported for commands for the second miscellaneous
function, regardless of the setting made with this parameter.
CQD The method used for determining the amount of travel in circular
interpolation is:
0 : Series 16 type.
1 : Series 15 type.
NPS A block that contains M98 Pxxx or M99, and which contains no addresses
other than O and N functions:
0 : As a one–block NC statement involving no movement.
(A single–block stop is caused.)
1 : As a macro statement.
(A single–block stop is not caused. Moreover, the block is not
regarded as a block involving no movement in tool–tip radius
compensation mode.)
3460
Address for second miscellaneous function
[Data type] Byte
This parameter specifies the address used for the second miscellaneous
function, as follows:
Address A B C U V W
Set value 65 66 67 85 86 87
Address B is assumed when a value other than the above is set.
Axes names cannot be used to specify the address.