B–63510EN/01
4. DESCRIPTION OF PARAMETERS
87
3122 Time interval used to record time data in operation history
[Data type] Word
[Unit of data] Minutes
[Valid data range] 0 to 1439
Time data is recorded in operation history at set intervals. When 0 is
specified in this parameter, 10 minutes is assumed as the default.
However, NOTE that time data is not recorded if there is no data to be
recorded at the specified time.
3123 Time until screen clear function is applied
[Data type] Bytes
[Unit of data] Minutes
[Valid data range] 1 to 255
This parameter specifies the period that must elapse before the screen
clear function is applied. If 0 is set, the screen is not cleared.
Moreover, this parameter is valid only when it is set on the path 1 side.
#7
D083124
#6
D07
#5
D06
#4
D05
#3
D04
#2
D03
#1
D02
#0
D01
D163125 D15 D14 D13 D12 D11 D10 D09
D243126 D23 D22 D21 D20 D19 D18 D17
3127 D25
[Data type] Bit
Dxx (xx: 01 to 25) When modal G code is displayed on the program check screen, the xx
group G code is:
0 : Displayed.
1 : Not displayed.
3132 Axis name (absoulute coordinate) for current position display
3133 Axis name (relative coordinate) for current position display
[Data type] Byte axis
[Valid data range] 0 to 255
These parameters set the axis name for current position display.
When G code system B or C is used, the axis name set in parameter
No.3132 is used for both absolute and relative coordinate axes.
The values set in these parameters are used only for display. For a
command address, the axis name set in parameter No.1020 is used.
When 0 is specified in these parameters, the value set in parameter
No.1020 is used.