4. DESCRIPTION OF PARAMETERS
B–63510EN/01
232
#7
8701
#6 #5 #4 #3 #2
WPR
#1 #0
[Data type] Bit
WPR The function that allows parameters that are rewritten using the PMC
window to be enabled during automatic operation is:
0 : Disabled.
1 : Enabled.
8760 Program number for data registration (power mate CNC manager)
[Data type] Word
[Valid data range] 0 to 9999
When the power mate CNC manager function is used, this parameter sets
the program numbers of the programs to be used for registering data
(parameters) from Power Mates.
For the parameters for a Power Mate in group n, the following program
numbers are used:
Setting + n 10 + 0
Example: When 8000 is set
8000: Parameters of group 0
8010: Parameters of group 1
8020: Parameters of group 2
8150: Parameters of group 15
8790 Timing for executing an auxiliary macro
[Data type] Word
[Unit of data]
This parameter sets the timing for executing a macro executor auxiliary
macro while NC programs, offset data, and so forth are being read or
punched out.
When as many characters as the number specified with this parameter are
read or punched out, an auxiliary macro is executed once. When 0 is set in
this parameter, no auxiliary macro is executed during read or punch
processing.
4.42
OTHER