4. DESCRIPTION OF PARAMETERS
B–63510EN/01
60
[Data type] Bit
CTS The servo motor–based speed control function is:
0 : Not used
1 : Used
DPS When servo motor–based speed control is applied, a position coder is:
0 : Used
1 : Not used
#7
1803
#6 #5 #4
TQF
#3 #2 #1
TQA
#0
TQI
[Data type] Bit
TQI While torque restriction is applied, in–position check is:
0 : Performed.
1 : Not performed.
TQA While torque restriction is applied, checking for an excessive error in the
stopped state/during movement is:
0 : Performed.
1 : Not performed.
TQF When torque control is performed by an axis control command of the
PMC axis control function, follow–up operation is:
0 : Not performed.
1 : Performed.
#7
1804
#6
SAK
#5
ANA
#4
IVO
#3 #2 #1 #0
[Data type] Bit axis
IVO When an attempt is made to release an emergency stop while the VRDY
OFF alarm ignore signal is 1:
0 : The emergency stop state is not released until the VRDY OFF alarm
ignore signal is set to 0.
1 : The emergency stop state is released.
NOTE
When a reset is issued while the VRDY OFF alarm ignore
signal is set to 1 and the motor activating current is low, the
reset state can also be released, provided this parameter is
set to 1.
ANA When an abnormal load is detected for an axis:
0 : Movement along all axes is stopped, and a servo alarm is output.
1 : No servo alarm is output, and movement along only the axes of the
group containing the axis with the abnormal load is stopped in interlock
mode. (The group number of each axis is set in parameter No.1881.)
SAK When the VRDY OFF alarm ignore signal IGNVRY is 1, or when the
VRDY OFF alarm ignore signals IGVRY1 to IGVRY4 are 1:
0 : Servo ready signal SA is set to 0.
1 : Servo ready signal SA remains set to 1.