Too much incident laser beam back to the resonator.
(Refer to DGN = 906 [878])
This alarm is issued, if a workpiece reflects laser beam more than the
rating to the laser oscillator. This can happen when the laser beam is used
to drill, cut, or weld materials (such as copper, brass, and aluminum)
having a high reflectivity to the laser beam (10.6 mm).
No. Cause of trouble Solution
1 Excessive returning beam
back into the resonator
Lower the output specified in the com-
mand, or take an action to reduce the
reflected laser beam.
2 Anomaly of parameter for
alarm detection
Check the settings of parameter Nos.
15265 [3982] and 15266 [3983] with the
corresponding values in the parameter
table attached to the unit.
3 Anomaly of parameter for
output power table
Check the settings of parameter Nos.
15280 to 15308 [265 to 294] with the
corresponding values in the parameter
table attached to the unit.
4 Anomaly of parameter for
input calibration coefficient
Set the parameter PRM. No. 15152
[259] to be the values as shown in the
attached table.
If rear mirror or power sensor was re-
placed, change the parameter.
Anomaly of power supply unit voltage of IF PCB
(Refer to DGN = 960/bit 0 [841/bit 0])
This alarm appears when there occurs the anomaly in the stabilized power
unit voltage 5, 15, 24V of IF PCB for NC interface.
No. Cause of trouble Solution
1 Fuse blowing
It is necessary to replace or adjust the
2 Anomaly of stabilized power
source unit
part. Call the FANUC service center.
3 Anomaly of power unit of IF
PCB
4 Laser oscillator main circuit
breaker abnormal
Anomaly of chiller unit (Refer to DGN = G221/bit 6 [145/bit6]
Setting the RUN (start pressure control) to ON causes the NC to output
a chiller unit start signal to the machine, which will respond with a chiller
unit ready signal. The NC monitors this signal. If the chiller ready signal
stops, the NC issues this alarm. Check the operation of the chiller.
Alarm No. 4068 [668]
Alarm No. 4069 [669]
Alarm No. 4070 [670]