B–70114EN/04
2. SAFETY
42
Press the emergency stop button when it is dangerous and breaks down.
The oscillator is stopped discharging, gas pressure control and stand by
purge state.
Use the one with the compulsion dissociation mechanism for the relay
used for the emergency stop circuit and the switch for welding prevention.
FANUC LASER C series are equipped with the warning light optionally.
The light is flashed during discharging and ready of laser beam emission.
Be careful of laser beam and high voltage.
To designer of laser processing machine
In EN60825–1, it needs the design with the fail safe or
redundant for warning equipment. The redundant warning
light is needed near the work–point of processing machine.
The warning light is prepared for the oscillator. Select this as
a warning light more than the second for the fail safe.
2.10
EMERGENCY STOP
BUTTON
2.11
WARNING LIGHT
(OPTIONAL)