B–63505EN/02
4.INTERFACE BETWEEN NC AND PMC
175
f : Available
– : Unavailable
Group
Symbol Signal name Address
T
series
M
series
*+ED1 to *+ED4 External deceleration signal G118 f f
*+L1 to *+L4 Overtravel signal G114 f f
*-ED1 to *-ED4 External decelerationsignal G120 f f
*-L1 to *-L4 Overtravel signal G116 f f
*ABSM Manual absolute signal G006#2 f f
*BECLP B-axis clamp completionsignal G038#7 - f
*BEUCP B-axis unclamp completionsignal G038#6 - f
*CRTOF Automatic erase CRT screen display cancel signal G062#1 f f
*DEC1 to *DEC4 Decelerationsignal for reference position return X1009 f f
*EAXSL Control axis selection status signal(PMC axis control) F129#7 f f
*ESP X1008#4 f f
*ESP
Emergency stop signal
G008#4 f f
*ESPA G071#1 f f
*ESPB
Emergency stop signal (serial spindle)
G075#1 f f
*FLWU Follow-up signal G007#5 f f
*
*FV0 to *FV7 Feedrate override signal G012 f f
*FV0E to *FV7E Feedrate override signal (PMC axis control) G151 f f
*FV0O to *FV7O Software operator's panel signal(*FV0 to *FV7) F078 f f
*HROV0 to *HROV6 1% step rapid traverse override signal G096#0 to #6 f f
*IT Interlock signal G008#0 f f
*IT1 to *IT4 Interlock signal for each axis G130 f f
*JV0 to *JV15 Manual feedrate override signal G010,G011 f f
*JV0O to *JV15O Software operator's panel signal(*JV0 to *JV15) F079,F080 f f
*SCPF Spindle clamp completion signal G028#5 f -
*SP Feed hold signal G008#5 f f
*SSTP Spindle stop signal G029#6 f f
*SSTP1 G027#3 f -
*SSTP2
Stop signal in each spindle
G027#4 f -
*SUCPF Spindle unclamp completionsignal G028#4 f -
*TLV0 to *TLV9 Tool life count override signal
G049#0 to
G050#1
- f
4.5
LIST OF SIGNALS