B–63785EN/01
2. 15i SERIES HARDWARE
219
The control units and various peripheral units provided by FANUC are
designed to be accommodated in closed cabinets. Usable cabinets are as
follows:
D Cabinets manufactured by machine tool builders to accommodate a
control unit and peripheral units
D Cabinets for a flexible turnkey system provided by FANUC
D Operation pendant (manufactured by the machine tool builder)
incorporating the control unit and operator’s panel
D Other equivalent items
The table below lists the environmental conditions for the control unit
within the cabinet.
Condition
Series 15i/150i,
(normal system)
When using heard
disk
Ambient Operating 0°C to 45°C 5°C to 40°C
temperature
of cabinet
Storage,
transportation
–20°C to 60°C
Ambient Operating 0°C to 55°C 5°C to 50°C
temperature
of unit
Storage,
transportation
–20°C to –60°C
Temperature
variation
1.1°C/minute maximum 0.3°C/minute maximum
Humidity Usually 75% or less
(relative humidity)
No condensation
10% to 75%
(relative humidity)
No condensation
Short term
(within 1 month)
95% or less
(relative humidity)
No condensation
10% to 90%
(relative humidity)
No condensation
Vibration Operating 0.5 G or less
Non–operating 1.0 G or less
Altitude Operating Up to 1000 m –60 to 1000 m
Non–operating –60 to 12,000 m
Atmosphere Normal machining factory environment. (A separate
study is required when the cabinets are used in an envi-
ronment exposed to relatively high levels of dust, cool-
ant, and organic solvents.)
2.18
ENVIRONMENTAL
CONDITIONS
OUTSIDE CABINET