APPENDIX
B–63785EN/01
B. ALARM LIST
487
Number ContentsMessage
SP0080 ALARM AT THE OTHER SP AMP. An alarm (AL–80) occurred on the spindle amplifier unit
For details, refer to the Serial Spindle User’s Manual.
SP0081 1–ROT MOTOR SENSOR ERROR An alarm (AL–81) occurred on the spindle amplifier unit
For details, refer to the Serial Spindle User’s Manual.
SP0082 NO 1–ROT MOTOR SENSOR An alarm (AL–82) occurred on the spindle amplifier unit
For details, refer to the Serial Spindle User’s Manual.
SP0083 MOTOR SENSOR SIGNAL ERROR An alarm (AL–83) occurred on the spindle amplifier unit
For details, refer to the Serial Spindle User’s Manual.
SP0084 SPNDL SENSOR DISCONNECTED An alarm (AL–84) occurred on the spindle amplifier unit
For details, refer to the Serial Spindle User’s Manual.
SP0085 1–ROT SPNDL SENSOR ERROR An alarm (AL–85) occurred on the spindle amplifier unit
For details, refer to the Serial Spindle User’s Manual.
SP0086 NO 1–ROT SPNDL SENSOR An alarm (AL–86) occurred on the spindle amplifier unit
For details, refer to the Serial Spindle User’s Manual.
SP0087 SPNDL SENSOR SIGNAL ERROR An alarm (AL–87) occurred on the spindle amplifier unit
For details, refer to the Serial Spindle User’s Manual.
SP0088 COOLING RADI FAN FAILURE An alarm (AL–88) occurred on the spindle amplifier unit
For details, refer to the Serial Spindle User’s Manual.
SP0097 OTHER SPINDLE ALARM An alarm (AL–97) occurred on the spindle amplifier unit
For details, refer to the Serial Spindle User’s Manual.
SP0098 OTHER CONVERTER ALARM An alarm (AL–98) occurred on the spindle amplifier unit
For details, refer to the Serial Spindle User’s Manual.
SP0110 AMP COMMUNICATION ERROR An alarm (AL–B0) occurred on the spindle amplifier unit
For details, refer to the Serial Spindle User’s Manual.
SP0111 CONV. LOW VOLT CONTROL An alarm (AL–B1) occurred on the spindle amplifier unit
For details, refer to the Serial Spindle User’s Manual.
SP0112 CONV. EX. DISCHARGE POW. An alarm (AL–B2) occurred on the spindle amplifier unit
For details, refer to the Serial Spindle User’s Manual.
SP0113 CONV. COOLING FAN FAILURE An alarm (AL–B3) occurred on the spindle amplifier unit
For details, refer to the Serial Spindle User’s Manual.
SP0120 COMMUNICATION DATA ERROR An alarm (AL–C0) occurred on the spindle amplifier unit
For details, refer to the Serial Spindle User’s Manual.
SP0121 COMMUNICATION DATA ERROR An alarm (AL–C1) occurred on the spindle amplifier unit
For details, refer to the Serial Spindle User’s Manual.
SP0122 COMMUNICATION DATA ERROR An alarm (AL–C2) occurred on the spindle amplifier unit
For details, refer to the Serial Spindle User’s Manual.
SP0201 MOTOR NUMBER DUPLICATE Two or more of the same motor Nos. other than “0” were set in
parameter No. 5841.
SP0202 SPINDLE SELECT ERROR A spindle No. exceeding the number of spindles were set in parameter
No. 5850.
SP0220 NO SPINDLE AMP. Either the cable connected to a serial spindle amplifier is broken, or the
serial spindle amplifier is not connected.
SP0221 ILLEGAL MOTOR NUMBER The spindle No. and the motor No. are incorrectly matched.
SP0222 CAN NOT USE ANALOG SPINDLE The machine tool does not support analog spindles.