4. INTERFACE BETWEEN THE NC AND PMC
B–63785EN/01
312
To switch the display from DI signals to DO signals or vice versa, press
soft key [DI/DO CHANGE].
To switch the display format between bit display and signal–by–signal
display, press soft key [DISPLY SELECT].
A display page can be selected using the page keys.
PAGE
PAGE
A signal can be displayed by specifying its address.
Method 1
(1) Press soft key [NUMBER SEARCH].
(2) Enter the address of a signal to be displayed.
(3) Press soft key [EXEC].
Method 2
(1) Enter the address of a signal to be displayed.
(2) Press soft key [NUMBER SEARCH].
Example of address entry
1. Address entry for bit display
“G67” A page containing signals related to G67 appears.
“67” If DI signals are displayed, a page containing signals
related to G67 appears.
If DO signals are displayed, a page containing
signals related to F67 appears.
(For bit displays, it is unnecessary to enter bit numbers.)
2. Address entry for signal–by–signal display
“G5.4” A page containing signals related to G5.4 appears.
“G5” A page containing signals related to G5.0 appears.
“5.4” If DI signals are displayed, a page containing signals
related to G5.4 appears.
If DO signals are displayed, a page containing
signals related to F5.4 appears.
NOTE
If an address that does not correspond to a signal is entered
for signal–by–signal display, a page containing a signal
whose address is higher than and nearest to the entered
address appears.
4.4.2
Screen Manipulation
D DI/DO signal switching
D Display switching
D Page switching
D Display of a specified
signal