B-63364EN/03 5. SETTING AND REGISTERING DATA FOR EACH CNC MACHINE
- 87 -
And you can use the special logical functions prepared in the
Machining Status Monitor Package for the condition formula. Refer
to "4. Special logical functions of the Machining Status Monitor
Package" in this paragraph for the special logical functions of the
Machining Status Monitor Package.
I/O type
Set the output method of outputting the logging data. The relation
between the set value and the output method is as follows.
0 : Overwrite output
Always the logging data is overwritten to the specified output
cell
1 : Additional output
The logging data is output downward from the specified output
cell
<Log data output worksheet>
AB
Specified top 1 Index 1 Index 2
cell position 2 Log1-1 Log2-1
3 Log1-2 Log2-2
4 Log1-3 Log2-3
NOTE
If you set the following conditions for outputting the logging data, the
logging data is accumulated in the worksheet of the logging output within a
short time.
Condition : None
I/O type : Additional output
When the logging data cannot be output because the logging data is too
much accumulated, the Machining Status Monitor Package creates the
new logging data output file and then continues to output the logging data.
Consequently many logging data output files are created in a short time
and the problems such that the capacity of the external memory device
becomes insufficient may occur.
Please set the condition so that the logging data output is reduced to
minimum when the logging data is output as the adding style.
In case that the logging data is output as the overwriting style, you are
recommended so as to set condition to prevent the decrease of the
performance of the Machining Status Monitor Package.